PD Series Specifications PD Series Dimensions 6 PERFORMANCE Rated capacities (1) (lbs.) 50, 100, 250, 500, 1K, 2K, 3K, 4K, 5K, 7.5K, 10K Rated Output (FSO) 2 mV/V Output Tolerance Nominal Combined Error Band ≤ 0.15 % FSO Non-Linearity ≤ 0.15 % FSO Hysteresis ≤ 0.15 % FSO Non-Repeatability ≤ 0.05 % of load Zero balance ± 2.0 % FSO Creep (20 Minutes) 0.05% of Load (1) (“K”= thousand) MECHANICAL Material Stainless steel Finish Natural Safe overload Compression 150 % FSO Tension 150 % FSO Side Load 2 % FSO Ultimate overload Compression 250% FSO Tension 250% FSO Side Load 5 % FSO Deflection See Dimensions Page Weight See Dimensions Page Mounting Bolt Torque ELECTRICAL Input Impedance 385 ±5 ohms (nominal) Output Impedance 350 ±3 ohms (nominal) Insulation Resistance >5000 Megohms @ 50VDC Excitation Voltage 10 V AC/DC (15 V maximum) Cable Color Code + Excitation (Red) - Excitation (Black) + Signal (Green) - Signal (White) Shield (Natural) Cable Type 4-conductor, 22 AWG, Polyurethane Jacket, Tinned Copper Braid, Diameter: 0.220” Cable Length See Dimensions Table Cable Termination Finished Conductors Cable Seal Compression Fitting/Strain Relief ENVIRONMENTAL Temperature, Operating -4 to +140 °F (-20 to +60°C) Temperature, Compensated 14 to +104 °F (-10 to +40°C) Temperature, Storage -40 to +170 °F (-40 to +77°C) Temperature Effects Zero < 0.0015% FSO/°F < 0.0026% FSO/°C Temperature Effects Output < 0.0008% of Rdg./°F < 0.0014% Rdg./°C Sealing IP67; Multi-redundant; Limited Immer- sion Tolerance FM Approval Intrinsically Safe: Non-Incendive: Class I, II, III; Div.1 Groups A-G Class 1; Div.2 Groups A-D Capacity (LB) D H H1 H2 R D1 D2 D3 N A DS DT HR HS HT T Deflect Weight DIMENSIONS (INCHES) 5K, 10K 4.12 1.37 0.12 0.25 0.625 0.28 .41 X 28 DP 3.50 8 4.50 1.00 2.75 3.41 2.81 3.25 0.60 0.010” 4.0 LBS 25K, 50K 4.75 2.12 0.50 0.31 0.875 0.34 .51 X .38 DP 4.00 4 5.00 1.60 3.25 4.17 3.29 3.79 0.72 0.010” 7.5 LBS 100K 5.43 2.25 0.25 0.31 0.875 0.41 .63 X .40 DP 4.60 8 6.00 1.60 4.25 4.55 3.67 4.42 0.97 0.010” 11.0 LBS