LA Series Specifications LA Series Dimensions Capacity (LBS) H L1 L2 L3 L4 L5 L6 L7 D Deflect Weight DIMENSIONS (INCHES) 3K 0.25 4.50 2.00 0.31 1.00 0.91 0.60 0.20 0.75 0.005” NOM 2.0 LBS 10K 0.25 4.75 2.00 0.31 1.00 1.13 0.63 0.20 1.00 0.005” NOM 2.5 LBS 15K 0.25 5.63 2.00 0.38 1.38 1.44 0.81 0.27 1.25 0.005” NOM 3.0 LBS 25K 0.25 6.13 2.00 0.50 1.63 1.56 0.94 0.27 1.50 0.005” NOM 3.7 LBS 50K 0.38 6.63 2.00 0.56 2.00 1.63 1.00 0.27 2.00 0.005” NOM 5.7 LBS 75K 0.50 7.63 2.00 0.63 2.50 1.88 1.25 0.27 2.50 0.005” NOM 10.5 LBS 100K 0.50 8.38 2.00 0.69 2.69 2.22 1.47 0.40 2.75 0.005” NOM 13.8 LBS 125K 0.63 8.75 2.00 0.69 3.00 2.31 1.44 0.40 3.00 0.005” NOM 17.2 LBS 160K 0.63 10.00 2.00 0.88 3.50 2.75 1.75 0.53 3.50 0.005” NOM 26.7 LBS 200K 0.75 11.75 2.00 1.00 4.00 3.50 2.25 0.53 4.00 0.005” NOM 41.0 LBS 300K 1.00 15.25 2.25 1.13 5.00 4.75 3.25 0.78 5.00 0.005” NOM 83.2 LBS 400K 1.13 17.75 2.25 1.38 6.00 5.63 3.88 0.78 6.00 0.005” NOM 140.0 LBS PERFORMANCE Rated capacities (1) (lbs.) 3K, 10K, 15K, 25K, 50K, 75K, 100K, 125K, 160K, 200K, 300K, & 400K Rated output (FSO) 2 mV/V Output Tolerance Nominal Combined Error Band ≤ 0.5 % FSO Non-Linearity ≤ 0.5 % FSO Hysteresis ≤ 0.5 % FSO Non-Repeatability ≤ 0.2 % FSO Side Load Rejection Ratio 500:1 Zero balance ± 2 % FSO Creep (20 minutes) 0.05 % of Load (1) (“K”= thousand) MECHANICAL Material Alloy tool steel (LA1) Stainless steel (LA3) Finish Natural Safe overload Compression 150 % FSO Tension 150 % FSO Side Load 100% FSO Ultimate overload Compression 300% FSO Tension 300% FSO Side Load: 200% FSO Deflection See Dimensions Page Weight See Dimensions Page ELECTRICAL Input Impedance 350 (nominal) Output Impedance 350 (nominal) Insulation Resistance >5000 Megohms @ 50VDC Excitation Voltage 10 V AC/DC (15 V maximum) Connector Pin Functions + Excitation (A) - Excitation (D) + (Optional) Remote Sense (E) - (Optional) Remote Sense (F) + Signal (B) - Signal (C) Shield (G) Cable Color Code + Excitation (red) - Excitation (black) + Signal (green) - Signal (white) Shield (natural) Cable Type 4-conductor, 22 AWG, Polyurethane Jacket, Tinned Copper Braid, Diameter: 0.220” Cable Length See Dimensions Table Cable Termination Finished Conductors Cable Seal Compression Gland Fitting ENVIRONMENTAL Temperature, Operating -65 to +250 °F (-54 to +120°C) Temperature, Compensated 15 to +115 °F (-9 to +46°C) Temperature, Storage -65 to +300 °F (-54 to +149°C) Temperature Effects Zero < 0.005% FSO/°F < 0.009% FSO/°C Temperature Effects Output < 0.008% of Rdg./°F < 0.014% Rdg./°C Sealing IP67; Multi-redundant; Limited Immersion Tolerance The temperature ratings provided do not include the companion cable/connector assembly. If PUR or PVC cable is employed, the maximum operating temperature is 180°F (82°C) 76